How It Works
A variable-area flowmeter (rotameter) measures flow by letting a free-floating "float" ride up and down inside a tapered tube — the higher it rises, the more flow is passing through. Most compact rotameters use a clear glass or plastic tube so you can watch the float directly, but the F56's metal tube is built for higher pressure, higher temperature, and harsher conditions where glass isn't an option. To keep the reading just as clear, a magnet inside the float communicates its position straight through the metal tube wall to the indicator outside — no window needed, nothing touching the process fluid, just a needle (and, on remote models, a live digital signal) that tracks the float in real time.
Learn more: What is a Rotameter?
Metal Construction for Demanding Conditions
A glass or plastic tube can crack under high pressure or heat — the F56's all-metal body doesn't have that limit. Depending on size and material, it handles pressure up to 42 MPa and media temperature up to 400°C, so it keeps reading accurately on steam lines, high-pressure gas service, and other duty a lighter-built flowmeter simply can't survive.
A Material for Every Process
Every F56 shares the same measuring principle — what changes is what touches your fluid. Pick the wetted material based on what's actually flowing through the line:
Stainless Steel (304 / 316 / 317) — The Everyday Workhorse
For water, steam, oil, and general chemical duty, 304 and 316 stainless steel cover most installations — 316 adds extra resistance to chlorides and mild acids, and 317 steps up further where 316 isn't quite enough. Low-carbon "L" grades (304L, 316L, 317L) resist the corrosion that welding can cause at the seam, making them the standard choice in food, beverage, and pharmaceutical lines where the meter is welded directly into the pipe.
PTFE-Lined Tube — For Aggressive Chemicals
When a process fluid is too corrosive for bare stainless steel, a full PTFE lining puts a chemically inert barrier between the fluid and the metal body, standing up to most strong acids and alkalis that would otherwise attack the tube. (PTFE lining is rated 0–80°C — see Specs for the full range.)
Hastelloy & Nickel — Built for Extreme Corrosion
For duty beyond what stainless steel or PTFE can take — hot hydrochloric or sulfuric acid, chlorine-bearing streams, or concentrated caustic soda — Hastelloy (B1/B2/C276) and pure nickel (N6) wetted parts hold up where ordinary metals would corrode away.
Titanium — Seawater and Oxidizing Acids
Titanium resists the chlorides and oxidizing acids that quickly attack stainless steel, making it the natural choice for seawater, bleach lines, and other chloride-heavy or oxidizing processes.
Zirconium — The Toughest Acid Duty
Zirconium is reserved for the most aggressive acid service — concentrated, near-boiling sulfuric or hydrochloric acid — where even Hastelloy reaches its limit.
PP & PV — Economical Plastic Construction
For utility water, dilute chemical dosing, and other mild-duty lines that don't need a full metal body, PP and PV plastic construction offers a lighter, lower-cost option for general plant service at ambient temperature (vertical mounting only, up to DN100).
One Flowmeter, However You Need to Read It
The F56 mounts the same way and measures the same flow whichever indicator you choose — so you're picking how you read it, not a different meter:
Simple Local Reading — P8
No wiring, no power, nothing to configure. The P8's polished stainless dial and mechanical needle give you a clear, at-a-glance flow reading right on the pipe — the natural fit for sanitary areas or anywhere you just need to see the flow, not transmit it.
Tie It Into Your Control System — P10
The P10 keeps the local needle and adds an LCD plus a loop-powered 4-20mA/HART output, so instantaneous flow, totals, and percent-of-scale reach your DCS or PLC over the same two wires. Available in intrinsically safe or flameproof versions, with optional high/low alarm switches that flag a flow excursion the moment it happens.
Local Reading, Hazardous-Area Ready — P10I
All the ruggedness of a flameproof enclosure with a straightforward local needle display — for sites that need Ex-rated protection without a remote signal. Add a switch and it can also trip a flow alarm right at the meter.
No Power Line? No Problem — P10B
Running conduit to a remote meter isn't always practical. The P10B runs on a single lithium battery — good for about a year — and still gives you a full LCD readout of instantaneous and totalized flow, wherever the installation happens to be.
Steady Readings, Even When Flow Isn't
A valve opening suddenly, or a pressure spike hitting the line, can send the float bouncing or spinning — and a jumpy float means a jumpy reading. On gas-service models, the F56 fits a self-centering damper machined from ultra-pure ceramic, so the float settles quickly and stays put. It won't corrode, won't wear down, and keeps your reading — and your 4-20mA signal — steady even when the process isn't.
F56 flowmeters are put to work across oil & gas, chemical, metallurgy, power, food & pharmaceutical, and pulp & paper processes — measuring and controlling liquid, gas, and steam flow wherever the line demands.
Specifications
| Specification |
Value |
| Model |
F56 |
| Media |
Liquid, gas, steam |
| Measuring range* |
Water |
10–300,000 L/h |
| Air |
0.7–3,000 Nm³/h |
| Turndown ratio |
10:1 |
| Accuracy class** |
Local needle (P8) |
1.0, 1.5, 2.0, 2.5 |
| Local digital, battery (P10B) |
1.0, 1.5, 2.0, 2.5 |
| Remote, needle + digital (P10/P10I) |
1.0, 1.5, 2.0, 2.5 |
| Media temperature*** |
Local needle (P8) |
-80°C to +300°C (PTFE lining: 0–80°C) |
| Digital & remote (P10, P10B, P10I) |
-40°C to +120°C (PTFE lining: 0–80°C) |
| Ambient temperature |
Local needle (P8) |
-40°C to +120°C |
| Digital & remote (P10, P10B, P10I) |
-20°C to +60°C |
| Media viscosity (excl. F56/SP) |
DN15: <1 mPa·s (F15.00–F15.03), <5 mPa·s (F15.04–F15.30) · DN25: <20 mPa·s · DN50–DN250: <30 mPa·s |
| Nominal pressure |
DN15–DN50 |
4.0 MPa (max: DN15/DN25 42 MPa, DN50 32 MPa) |
| DN80–DN250 |
1.6 MPa (max: DN80 10 MPa, DN100 6.4 MPa, DN125/DN150 4.0 MPa, DN200/DN250 2.5 MPa) |
| Process connection |
Flange (DIN2501 / ANSI / JIS — DIN recommended); sanitary tri-clamp, threaded, and compression fitting available to order |
| Electrical connection |
M20×1.5, 1/2"G, 1/2"NPT, 3/4"G, 3/4"NPT |
| Mounting orientations |
Vertical, horizontal, top-in bottom-out (vertical lines), bottom-in side-out, side-in side-out |
| Straight pipe run |
Inlet ≥5×DN · Outlet ≥250 mm |
| Enclosure rating |
IP67 |
| Explosion-proof rating |
Ex ia IIC T4/T5/T6 Ga (intrinsically safe) · Ex d IIC T6 Gb (flameproof) · Certificate CE16.1206X |
| Intrinsic safety parameters |
Ui=28V, Ii=93mA, Pi=0.65W, Ci≤5nF, Li=0mH (barrier: Uo≤28V, Io≤93mA, Po≤0.65W, Co≥Ci+Ccable, Lo≥Li+Lcable) |
| Output signal |
2-wire (4-20)mA / HART protocol |
* Measuring range shown at reference conditions: clean water at 20°C, air at 20°C / 0.1013MPa absolute; special ranges available on request.
** Accuracy class is verified per the German VDI/VDE 3513 standard at 10 points across the scale (10%–100% of full flow). Since accuracy is stated as % of full-scale reading, real-world accuracy is best when normal operating flow sits in the upper half of the selected range.
*** A high-temperature option (H1/H2/H3 order codes) extends media temperature up to 400°C on any indicator type — specify at order time.
Product Size
All mounting forms accept any indicator type (P8/P10/P10I/P10B) on the same measuring tube.
Vertical Mounting

Unit: mm
| DN |
H |
L |
L1 |
| DN15 |
250 |
156 |
75 |
| DN20 |
250 |
162 |
80 |
| DN25 |
250 |
165 |
84 |
| DN32 |
250 |
171 |
90 |
| DN40 |
250 |
177 |
95 |
| DN50 |
250 |
180 |
98 |
| DN65 |
250 |
187 |
106 |
| DN80 |
250 |
194 |
112 |
| DN100 |
250 |
203 |
122 |
| DN125 |
400 |
213 |
131 |
| DN150 |
400 |
225 |
145 |
| DN200 |
450 |
245 |
170 |
| DN250 |
450 |
253 |
183 |
Side-In / Side-Out Mounting

Unit: mm
| DN |
H |
H1 |
B |
| DN15 |
200 |
500 |
100 |
| DN20 |
200 |
500 |
100 |
| DN25 |
200 |
500 |
100 |
| DN32 |
200 |
500 |
100 |
| DN40 |
250 |
600 |
120 |
| DN50 |
250 |
600 |
120 |
| DN65 |
350 |
700 |
160 |
| DN80 |
350 |
700 |
160 |
| DN100 |
350 |
750 |
180 |
| DN125 |
400 |
800 |
250 |
| DN150 |
450 |
850 |
250 |
Bottom-In / Side-Out Mounting

Unit: mm
| DN |
H |
H1 |
B |
| DN15 |
200 |
500 |
100 |
| DN20 |
200 |
500 |
100 |
| DN25 |
200 |
500 |
100 |
| DN32 |
200 |
500 |
100 |
| DN40 |
250 |
600 |
120 |
| DN50 |
250 |
600 |
120 |
| DN65 |
350 |
700 |
160 |
| DN80 |
350 |
700 |
160 |
| DN100 |
350 |
750 |
180 |
| DN125 |
400 |
800 |
250 |
| DN150 |
450 |
850 |
250 |
Horizontal Mounting

Unit: mm
| DN |
H |
H1 |
| DN15 |
200 |
255 |
| DN20 |
200 |
255 |
| DN25 |
200 |
255 |
| DN32 |
250 |
250 |
| DN40 |
250 |
245 |
| DN50 |
250 |
245 |
| DN65 |
300 |
255 |
| DN80 |
350 |
270 |
| DN100 |
350 |
280 |
| DN125 |
400 |
415 |
| DN150 |
450 |
440 |
| DN200 |
500 |
520 |
P8 Local Indicator — Standard Dimensions

Unit: mm
| DN |
H |
L |
L1 |
| DN15 |
250 |
87 |
69 |
| DN20 |
250 |
93 |
74 |
| DN25 |
250 |
96 |
78 |
| DN32 |
250 |
102 |
84 |
| DN40 |
250 |
108 |
89 |
| DN50 |
250 |
111 |
92 |
| DN65 |
250 |
118 |
100 |
| DN80 |
250 |
122 |
107 |
| DN100 |
250 |
128 |
116 |
| DN125 |
400 |
133 |
126 |
| DN150 |
400 |
139 |
140 |
| DN200 |
450 |
150 |
165 |
| DN250 |
450 |
155 |
178 |
Flange Bolt Pattern (ANSI B16.5 / DIN2501)

Unit: mm
| Size (ANSI B16.5, 150lb) |
D |
k |
b |
d3 |
f |
n |
d2 |
| 1/2" |
88.9 |
60.5 |
11.2 |
35.1 |
1.6 |
4 |
15.7 |
| 3/4" |
98.6 |
69.9 |
12.7 |
42.9 |
1.6 |
4 |
15.7 |
| 1" |
108.0 |
79.2 |
14.2 |
50.8 |
1.6 |
4 |
15.7 |
| 1-1/4" |
117.3 |
88.9 |
15.7 |
63.5 |
1.6 |
4 |
15.7 |
| 1-1/2" |
127.0 |
98.6 |
17.5 |
73.2 |
1.6 |
4 |
15.7 |
| 2" |
152.4 |
120.7 |
19.1 |
91.9 |
1.6 |
4 |
19.1 |
| 2-1/2" |
177.8 |
139.7 |
22.4 |
104.6 |
1.6 |
4 |
19.1 |
| 3" |
190.5 |
152.4 |
23.9 |
127.0 |
1.6 |
4 |
19.1 |
| 4" |
228.6 |
190.5 |
23.9 |
157.2 |
1.6 |
8 |
19.1 |
| 5" |
254.0 |
215.9 |
23.9 |
185.7 |
1.6 |
8 |
22.4 |
| 6" |
279.4 |
241.3 |
25.4 |
215.9 |
1.6 |
8 |
22.4 |
| 8" |
342.9 |
298.5 |
28.4 |
269.7 |
1.6 |
8 |
22.4 |
| 10" |
428.4 |
362.0 |
30.2 |
323.9 |
1.6 |
12 |
25.4 |
| DN / PN (DIN2501) |
D |
k |
b |
d3 |
f |
n |
d2 |
| 15/4.0 |
95 |
65 |
16 |
45 |
2 |
4 |
14 |
| 20/4.0 |
105 |
75 |
16 |
55 |
2 |
4 |
14 |
| 25/4.0 |
115 |
85 |
18 |
68 |
2 |
4 |
14 |
| 32/4.0 |
140 |
100 |
18 |
76 |
2 |
4 |
18 |
| 40/4.0 |
150 |
110 |
18 |
86 |
2 |
4 |
18 |
| 50/4.0 |
165 |
125 |
20 |
102 |
3 |
4 |
18 |
| 65/1.6 |
185 |
145 |
18 |
120 |
3 |
4 |
18 |
| 80/1.6 |
200 |
160 |
20 |
138 |
3 |
8 |
18 |
| 100/1.6 |
220 |
180 |
20 |
162 |
3 |
8 |
18 |
| 125/1.6 |
250 |
210 |
22 |
188 |
3 |
8 |
18 |
| 150/1.6 |
285 |
240 |
22 |
218 |
3 |
8 |
22 |
| 200/1.6 |
340 |
295 |
24 |
268 |
3 |
12 |
22 |
| 250/1.6 |
405 |
355 |
26 |
325 |
3 |
12 |
26 |
Tri-Clamp / Sanitary Connection

Unit: mm
| DN |
D |
P |
L |
L1 |
| DN15 |
34.0 |
27.5 |
156 |
75 |
| DN20 |
34.0 |
27.5 |
162 |
80 |
| DN25 |
50.5 |
43.5 |
165 |
84 |
| DN32 |
50.5 |
43.5 |
171 |
90 |
| DN40 |
50.5 |
43.5 |
177 |
95 |
| DN50 |
64.0 |
56.5 |
180 |
98 |
| DN65 |
91.0 |
83.5 |
187 |
106 |
| DN80 |
106.0 |
97.0 |
194 |
112 |
| DN100 |
119.0 |
110.0 |
203 |
122 |
Used across oil & gas, chemical, metallurgy, power, food & pharmaceutical, and pulp & paper processes for liquid, gas, and steam flow measurement and process control.