[Discontinued] F20 Series - 192 mm middle size pipe size 1/2"-3/4" patented dual-indicator flow meter

Patented dual-indicator
Laser engraved degree scales  
Apply for 
Water treatment
PCB│Cleaning

Download Product Catalogue


 

F10 series has been discontinued. Please select our  new F201 series instead.

General Features
  • Patented dual-indicator design for easy and clear flow range management.
  • Laser engraved degree scales provide better readability and longer life.
  • Available in customizable units and specific gravity (SG).
  • Each batch of flow meters will be calibrated before delivery for our best
    precision guarantee.
  • Perpendicular joint is available for space saving installation.
  • Hastelloy float is available for specific high PH liquid usage.
  • Operating Conditions

      Full Scale Accuracy: ±5%.

     ● Max. working pressure: 6.0kg/cm²

LORRIC Flowmeter

 


 
 
 
Why LORRIC Flow Meters?

「ACCURACY」is everything!

Patented dual-indicator

Patented dual-indicator design for easy and clear flow range management.

Laser engraved degree scales

Laser engraved degree scales provide better readability and longer life.

Delicate machining for float

We produce float based on our over 20 years of solid machining experience of producing nozzles. It leads every float got best and stable quality and excellent flow distribution for best on-site performance.
LORRIC Flowmeter
LORRIC Flowmeter
LORRIC Flowmeter

 

Specs

Please place your order according below information.


How to pleace an order for LORRIC flowmeters?

  • • You can find the exact Capacity Code according to your requirement of pressure, flow, and spray angle as the capacity & angle chart we provided above.
  • • Please refer to following order example for placing order to LORRIC.
  •   Example :LORRIC Flowmeter

table
LORRIC Flowmeter
Series F20 PC F20 PSU F20H PSU F20A PSU / F20AH AIR
Applicable Fluid

Tap Water

Chemical and Non-organic Solvents

When chemicals are corrosive to stainless steel

Air
Body Material PC PSU PSU PSU
Float Material AISI 316 AISI 316 Ti / Hastelloy C PVC / AISI 316 / Hastelloy C
Guide Rod Material AISI 316 / Ti
O-ring Material
EPDM / VITON
Union Nuts Material UPVC / Aluminum
Guide Rod Bottom Material UPVC / PSU
Scale Range(L/min) 1.0 - 10 L/min 3.0 - 30 NLPM
1.5 - 15 L/min 5.0 - 50 NLPM
2.0 - 20 L/min 10 - 100 NLPM
3.0 - 30 L/min 35 - 350 NLPM
4.0 - 40 L/min 50 - 500 NLPM
5.0 - 50 L/min 100 - 1000 NLPM 
Adaptor Size and Adaptor Material
1/2"
Male Thread BSPT UPVC / PP 
Female Thread BSPT UPVC / PP 
NPT UPVC
Welding Type
UPVC
Butt-fusion Adaptor  PP
3/4"
Male Thread
BSPT UPVC / PSU / PP 
NPT UPVC
Female Thread BSPT UPVC / PSU / PP
NPT UPVC

 Panel Elbow Male Thread

BSPT PVC
Panel Elbow Welding Type UPVC
Welding Type UPVC
Butt-fusion Adaptor
PP
  • * Liquid flow meters are calibrated for 20°C water. Gas flow meters are calibrate for normal condition. ( 0°C , 1 atm)
  • * All adaptors can be manufactured to order, please contact us for price and lead time.
  • * Above temperature information is for reference only and may not be applicable for all environments.
Size
                                                                                                        Unit:mm  
Adapter Spec   A     B   C   D     E   Panel Elbow Weight
(g)
F G   H     i  
3/4"Male Thread 192 104 44 51 56.5 - - - -
3/4"Female Thread 189 104 42.5 51 56.5 - - - -
3/4"CNS 199 104 47.5 51 56.5 - - - -
3/4"ASTM 189 104 47.5 51 56.5 - - - -
3/4"JIS 199 104 47.5 51 56.5 - - - - 135
3/4"DIN 196 104 46 51 56.5 - - - -
3/4"JIS MAX 194 104 45 51 56.5 - - - -
PP OD32 
ID26
181 104 38.5 51 56.5 - - - -
PP
OD32.2 
ID26.2
192 104 44 51 56.5 - - - -
PP OD32 
ID24
187 104 41.5 51 56.5 - - - -
1/2"Male Thread 192 104 44 51 56.5 - - - -
1/2"Female Thread 184 104 40 51 56.5 - - - -
1/2"CNS 185 104 40.5 51 56.5 - - - -
1/2"ASTM 184 104 40 51 56.5 - - - -
1/2"JIS 185 104 40.5 51 56.5 - - - -
1/2"DIN 188 104 42 51 56.5 - - - -
Panel Elbow
- 104 - 51 56.5 182 221 55.5 21.2
3/4"PT
Panel Elbow
Male Thread
- 104 - 51 56.5 180 219 55 27
 
 
 
 
 
 
-Panel Elbow-
 
Panel Elbow
Installation S
ize
         J                   K                   L         
33.5
ø26.6 ø32.6
 
 
 
 
 
 
 
 -Panel Elbow Male Thread-
 
Panel Elbow
Installation S
ize
J K L M    N    O
P
ø21.2
43.7 25.0 2.30 24.0 ø26.6
ø32.6

 

 

                             LORRIC Flowmeter

 

 

 

 

 

 

 

Installation
Step 1.
Please set up pipes vertically
Step 2.
Disassemble adaptors form flow meter body both ends
Step 3.
Connect adaptors with pipes (include union nuts)
LORRIC Flowmeter
LORRIC Flowmeter
LORRIC Flowmeter

 

Step 3-1.
Thread type: Wrap up Teflon tape around first for tight connection

 

Step 3-2.
Welding Type: Gluing adaptors and pipes, connect both together

 

Step 4.
After glue dried and getting steady, tightly connect adaptor with body with buts by hand

 

LORRIC Flowmeter
LORRIC Flowmeter
LORRIC Flowmeter

Detailed installation instructions


 

 


 

+886-978-005-235
[email protected]